. 2013; 41(8): 691-696 | DOI: 10.5543/tkda.2013.51882  

Koroner yavaş akım fenomeni saptanan hastalarda sol ventrikül sistolik ve diyastolik fonksiyonlarının değerlendirilmesi

Cemil Zencir1, Mustafa Çetin2, Hasan Güngör1, Kayıhan Karaman3, Çağdaş Akgüllü1, Ufuk Eryılmaz1, Mücahit Avcil4
1Adnan Menderes Üniversitesi Tıp Fakültesi, Kardiyoloji Anabilim Dalı, Aydın
2Adıyaman Üniversitesi Tıp Fakültesi, Kardiyoloji Anabilim Dalı, Adıyaman
3Gaziosmanpaşa Üniversitesi Tıp Fakültesi Kardiyoloji Anabilim Dalı, Tokat
4Adnan Menderes Üniversitesi Tıp Fakültesi, Acil Tıp Anabilim Dalı, Aydın

Amaç: Bu çalışmada, koroner yavaş akım fenomeni (KYAF) olan hastalarda geleneksel ve doku Doppler ekokardiyografi ile ölçülen sol ventrikül sistolik ve diyastolik fonksiyon parametreleri kontrol grubuyla karşılaştırıldı.
Çalışma planı: Çalışmaya koroner anjiyografi sırasında KYAF saptanan 60 hasta (49 erkek; ortalama yaş 52.4±12.1) ve normal koroner arterler saptanan 30 gönüllü (21 erkek; ortalama yaş 50.2±12.1) alındı. Koroner yavaş akım fenomeni tanısı TIMI kare sayısı (TKS) yöntemiyle konuldu. Her bir koroner arterin TIMI kare sayısı TKS yöntemiyle hesaplandı. Gelenekselve doku Doppler ekokardiyografi ile sol ventrikülün sistolik ve diyastolik fonksiyonları değerlendirildi. Diyastolik fonksiyon parametreleri ile TKS bağıntısı araştırıldı.
Bulgular: Gruplar arasında bazal demografik ve laboratuvar sonuçları arasında anlamlı fark yoktu. TKS, KYAF grubunda yüksekti (p<0.001). Geleneksel ekokardiyografik incelemede sol ventrikül ejeksiyon fraksiyonu (EF), E/A oranı ve izovolemik gevşeme zamanı (IVRT) benzerdi (sırasıyla, %65.93±8.06 ve 66.63±5.96, 1.11±0.36 ve 1.22±0.33, 85±17 cm/sn ve 84±13 cm/sn, tüm p değerleri >0.05). Doku Doppler ile ekokardiyografik incelemede grupların Em, Am ve E/Em oranı benzer idi (sırasıyla, 7.0±2.1cm/s ve 7.4±1.7, 7.4±2.0 cm/sn, 7.0±1.4 cm/sn, 10±3 ve 10±1, tüm p değerleri >0.05). Sol inen koroner arterin (LAD) düzeltilmiş TKS (cLAD) ve ortalama TKS ile E/A oranı, DT, IVRT ve E/Em oranı arasında anlamlı bağıntı saptanmadı.
Sonuç: Çalışmamızda koroner yavaş akım fenomeni olan hastalardaki sol ventrikülün sistolik ve diyastolik fonksiyonlarının korunmuş olduğu saptandı.

Anahtar Kelimeler: Ekokardiyografi, Doppler, esneklik görüntüleme teknikleri/yöntemler; ventrikül fonksiyonu, sol; yavaş akım fenomeni.


Evaluation of left ventricular systolic and diastolic functions in patients with coronary slow flow phenomenon

Cemil Zencir1, Mustafa Çetin2, Hasan Güngör1, Kayıhan Karaman3, Çağdaş Akgüllü1, Ufuk Eryılmaz1, Mücahit Avcil4
1Adnan Menderes University Faculty Of Medicine, Cardiology Deparment, Aydın, Turkey
2Adiyaman University Faculty Of Medicine, Cardiology Deparment, Adıyaman, Turkey
3Gaziosman Pasa University Faculty Of Medicine, Cardiology Deparment, Tokat, Turkey
4Adnan Menderes University Faculty Of Medicine, Emergency Medicine Deparment, Aydın, Turkey

Objectives: In this study, systolic and diastolic function parameters were measured with conventional and tissue Doppler echocardiography in coronary slow flow phenomenon (CSFP) patients and compared to those of a control group.
Study design: Sixty patients (49 male; mean age 52.4±12.1) in whom CSFP was detected during coronary angiography study and 30 volunteers with normal coronary arteries (21 males; mean age 50.2±12.1) were included in this study. CSFP was determined using the TIMI frame count (TFC) method. TIMI frame count was calculated in each coronary artery using the TFC method. Left ventricular systolic and diastolic function was assessed by conventional echocardiography and tissue Doppler imaging. TFC correlation between diastolic function parameters was measured.
Results: Baseline demographic and laboratory results did not differ significantly between the groups. TIMI frame counts were greater in the CSFP group compared to controls (p<0.001). Left ventricular ejection fraction (65.93±8.06% vs 66.63±5.96%), E/A ratio (1.11±0.36 vs 1.22±0.33), and isovolumetric relaxation time (IVRT) (85±17 cm/s vs 84±13 cm/s) measured with conventional echocardiography showed no significant difference between the two groups. Em (7.0±2.1 cm/s vs 7.4±1.7 cm/s), Am (7.4±2.0 cm/s vs 7.0±1.4 cm/s) and E/Em (10±3 vs 10±1) measured with tissue Doppler echocardiography showed no significant difference between the two groups. Corrected TIMI frame count for the left descending coronary artery (cLAD) and mean TFC were not correlated with the E/A ratio, deceleration time (DT), IVRT, or E/Em ratio.
Conclusion: Left ventricular systolic and diastolic functions were preserved in CSFP.

Keywords: Echocardiography, Doppler, elasticity imaging techniques/ methods; ventricular function, left; slow flow phenomenon


Cemil Zencir, Mustafa Çetin, Hasan Güngör, Kayıhan Karaman, Çağdaş Akgüllü, Ufuk Eryılmaz, Mücahit Avcil. Evaluation of left ventricular systolic and diastolic functions in patients with coronary slow flow phenomenon. . 2013; 41(8): 691-696

Sorumlu Yazar: Cemil Zencir, Türkiye


ARAÇLAR
Tam Metin PDF
Yazdır
Alıntıyı İndir
RIS
EndNote
BibTex
Medlars
Procite
Reference Manager
E-Postala
Paylaş
Yazara e-posta gönder

Benzer makaleler
Google Scholar