Red Marrow Absorbed Dose Calculation in Thyroid Cancer Patient using A Simplified Excel Spreadsheet

Rangsee Songprakhon1, Krisana Roysri1, Putthiporn Charoenphun2, Krisanat Chuamsaamarkkee2
1Division of Nuclear Medicine, Department of Radiology, Surin Hospital, Thailand
2Division of Nuclear Medicine, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Thailand

INTRODUCTION: Absorbed dose to red marrow ("D" _"rm" ) can be calculated using blood dosimetry. However, completed blood method is laborious and invasive. Therefore, image-based dosimetry is the method of choice. Nonetheless, commercial software is expensive. The goal of this work was to develop a simplified Excel spreadsheet for image-based radioiodine red marrow dosimetry.
METHODS: The serial whole-body images (acquired at 2, 6, 24, 48, and 72 hours) of 29 patients from the routine pre-therapeutic dosimetry protocol were retrospectively reanalyzed. In routine, the commercial OLINDA/EXM image-based dosimetry software was used to calculate the whole-body time-integrated activity coefficient (〖"TIAC" 〗_"WB" ) and "D" _"rm" (in term of absorbed dose coefficient (d_rm)). For a simplified Excel spreadsheet, the whole-body count was obtained from the vendor supplied software. Then, the 〖"TIAC" 〗_"WB" was computed by fitting time-activity curve using Excel function. S-factor was taken from other publications and scaled according to the patient-specific mass. A comparison of the 〖"TIAC" 〗_"WB" and d_rm from two methods was analyzed using a non-inferiority test based on a paired t-test or the Wilcoxon signed rank test.
RESULTS: The 〖"TIAC" 〗_"WB" showed no significant difference between two methods (p-value 0.243 with a paired t-test). The calculated "d" _"rm" " " from a simplified Excel spreadsheet was assumed to be statistically non-inferior to the commercial OLINDA/EXM image-based dosimetry software with the non-inferiority margin of 0.02 (p-value < 0.05 with the Wilcoxon signed rank test).
DISCUSSION AND CONCLUSION: The dose assessment from a simplified Excel spreadsheet is feasible and relatively low cost compared to the commercial OLINDA/EXM image-based dosimetry software

Keywords: red marrow absorbed dose, image-based dosimetry, radioiodine therapy, internal dosimetry


Rangsee Songprakhon, Krisana Roysri, Putthiporn Charoenphun, Krisanat Chuamsaamarkkee. Red Marrow Absorbed Dose Calculation in Thyroid Cancer Patient using A Simplified Excel Spreadsheet. . 2020; 29(3): 124-131

Corresponding Author: Krisanat Chuamsaamarkkee, Thailand


TOOLS
Print
Download citation
RIS
EndNote
BibTex
Medlars
Procite
Reference Manager
Share with email
Share
Send email to author

Similar articles
Google Scholar