. 1989; 2(1): 17-21

Measurement of 99mTc-MDP Adsorption of Some Dental Alloys

Nesrin Anıl1, Cihat Çekiç2, Meral Tayan Ercan2, Mehmet Mutlu2
1From Department of Prosthetic Dentistry, Faculty of Dentistry, Department of Nuclear Medicine, Faculty of Medicine, Hacettepe University, Ankara, Türkiye.
2From Department of Chemical Engineering, Faculty of Engineering, Hacettepe University, Ankara, Türkiye.

Test samples of five different dental alloys were prepared in discs 10 mm in diameter and 1.5 mm thick. Their surfaces were sandblasted, ground with sand paper, polished and electrolyzed in succession. 10 samples of each alloy in each surface finishing were prepared Surface roughness of each disc was determined by the use of a profilometre. The adsorption of the surfaces was measured by 99mTc-MDP both before and after 2 h of exposure to oral environment. The results indicated that the discs sandblasted and electrolyzed had the maximum and those polished the minimum surface roughness. The adsorption showed variation according to surface roughness and to the alloy type prior to exposure to oral environment. Alloy samples with different surface roughness placed in the oral cavity exhibited similar adhesive properties.

Keywords: Dental alloys, Surface roughness, 99mTc-MDP adsorption, Oral environment.


Nesrin Anıl, Cihat Çekiç, Meral Tayan Ercan, Mehmet Mutlu. Measurement of 99mTc-MDP Adsorption of Some Dental Alloys. . 1989; 2(1): 17-21

Sorumlu Yazar: Nesrin Anıl, Türkiye